3-12
5. EMERGENCY STOW PROCEDURE
In the unlikely event there is a hydraulic system failure and the manual backup pump is
inoperative, the lift may be stowed as follows by two or more able-bodied persons:
WARNING
MANUALLY STOWING OF THIS LIFT REQUIRES FORCES GREATER THAN 100 LBS.
DO NOT ATTEMPT TO MANUALLY STOW THE LIFT USING LESS THAN TWO
PEOPLE.
WARNING
THE PLATFORM IS HEAVY AND SHOULD BE LIFTED WITH USING EXTREME
CAUTION AND PROPER LIFTING TECHNIQUE:
ALWAYS LIFT WITH LEGS AND NOT THE BACK
WHEN ATTEMPTING TO LIFT HEAVY OBJECTS.
• Using ONE PERSON ON EACH SIDE of platform, raise platform until rollstop closes and
place temporary support block on each side of lifting frame.
• At front of lift, position PLATFORM LOCK HANDLE to RIGHT and push sliding platform
INWARD until it locks.
• Using ONE PERSON ON EACH SIDE of platform, raise platform at least 1-inch above stow
level and lower platform to stow level.
• Remove temporary support block.
• Release and lower LEFT handrail into stowed position then release and lower RIGHT
handrail.
WARNING
TO PREVENT PINCHING FINGERS, PUSH PLATFORM INWARD USING AN OPEN,
FLAT HAND AND EXTREME CAUTION.
• At left-side of lift enclosure, pull and hold manual release handle OUTWARD, then push
platform INWARD to its fully stowed position.
• If equipped with optional lift cover, close and latch cover.
-BACK TO TABLE OF CONTENTS- -GO TO NEXT CHAPTER-