2-10
3. LIFT STOW LEVEL SETTING
The following procedure provides for setting the proper platform location as the platform
approaches stow level from above (vehicle floor level). Adjustment requires setting two (2)
setscrews that determine the platform position as it encounters the left/right rocker stop bars.
The proper stow level is achieved when the lift stows without interference as it moves along the
lift guide rails located inside the lift enclosure assembly.
a. Deploy the lift. This procedure may be performed without raising handrails and/or deploying
sliding platform.
b. Refer to Figure [2-8]. Be certain that the sliding platform guide rails make contact with the
rocker stop bars.
FIGURE [2-8]: STOW LEVEL ADJUSTMENT
c. Gain access to underside of platform.
d. Loosen lock-nuts from against the left and right rocker stop bars.
e. From the underside of the rocker stop bars, turn setscrews against guide rails clockwise to
raise lift stow level setting, or counter-clockwise to lower lift stow level setting.
NOTE: Be sure to adjust setscrews on both sides of lifting frame simultaneously. This will
ensure proper leveling of platform.
f. Repeat this procedure and adjust stow level position as required.
g. When the exact stow level has been achieved, tighten lock-nuts against rocker stop bars.